SYNOPTICS-TOKENRING-MIB -- Token Ring MIB 3.1 -- DRAFT Revision 10/25/91 -- Printed 10/29/91 -- Copyright 1991 SynOptics Communications, Inc. All Rights -- Reserved. Reproduction of this document is authorized on -- condition that the foregoing copyright notice is included. -- This SynOptics SNMP Management Information Base Specification -- (Specification) embodies SynOptics' confidential and -- proprietary intellectual property. SynOptics retains all -- title and ownership in the Specification, including any -- revisions. -- -- It is SynOptics intent to encourage the widespread use of -- this Specification in connection with the management of -- SynOptics products. SynOptics grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of SynOptics products. -- -- This Specification is supplied "AS IS," and SynOptics makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. DEFINITIONS ::= BEGIN -- SECTION 1: Top Level Definitions -- Imports IMPORTS Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 s3000TokenRing FROM SYNOPTICS-COMMON-MIB; -- Groups s3000TrBoard OBJECT IDENTIFIER ::= { s3000TokenRing 2 } s3000TrPort OBJECT IDENTIFIER ::= { s3000TokenRing 3 } s3000TrNmm OBJECT IDENTIFIER ::= { s3000TokenRing 4 } s3000TrNode OBJECT IDENTIFIER ::= { s3000TokenRing 5 } s3000TrRing OBJECT IDENTIFIER ::= { s3000TokenRing 7 } s3TrRingStats OBJECT IDENTIFIER ::= { s3000TrRing 1 } -- SECTION 2: Token Ring Board Group -- Common Board Table s3TrCommonBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrCommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Information maintained for each token ring board. The information can be retrieved for any token ring board, even if the board is not on the same backplane ring as this NMM. The instance is the slot number of the concentrator that the board occupies." ::= { s3000TrBoard 2 } s3TrCommonBoardEntry OBJECT-TYPE SYNTAX S3TrCommonBoardEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "There is one entry per board in this table." INDEX { s3TrCommonBoardIndex } ::= { s3TrCommonBoardTable 1 } S3TrCommonBoardEntry ::= SEQUENCE { s3TrCommonBoardIndex INTEGER, s3TrCommonBoardRing1or2 INTEGER, s3TrCommonBoardRingSpeed INTEGER } s3TrCommonBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If a board is inserted or reinserted in a concentrator then the NMM has to be reinitialized." ::= { s3TrCommonBoardEntry 1 } s3TrCommonBoardRing1or2 OBJECT-TYPE SYNTAX INTEGER { other(1), -- not a valid ring number ring1(2), -- use/using ring 1 on the concentrator ring2(3) -- use/using ring 2 on the concentrator } ACCESS read-only STATUS mandatory DESCRIPTION "Determines which ring the board is currently using on the concentrator backplane." ::= { s3TrCommonBoardEntry 2 } s3TrCommonBoardRingSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown speed speed1M(2), -- 1 Mbps for standard compatibility speed4M(3), -- 4 Mbps speed16M(4) -- 16 Mbps } ACCESS read-only STATUS mandatory DESCRIPTION "Token Ring speed of the ring that this board is connected to." ::= { s3TrCommonBoardEntry 3 } -- SECTION 3: Token Ring Port Group -- Port Table s3TrPortTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing information about each port of a LattisNet concentrator. The number of entries is given by knowing the number of occupied slots in s3ChassisSlotConfigTable whose s3SlotModuleType is of a token ring type and is on the same physical ring as the agent NMM." ::= { s3000TrPort 1 } s3TrPortEntry OBJECT-TYPE SYNTAX S3TrPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A port entry containing objects at the port level for a particular port." INDEX { s3TrPortBoardIndex, s3TrPortIndex } ::= { s3TrPortTable 1 } S3TrPortEntry ::= SEQUENCE { s3TrPortBoardIndex INTEGER, s3TrPortIndex INTEGER, s3TrPortWrap INTEGER, s3TrPortTestLatch INTEGER, s3TrPortRelayStatus INTEGER, s3TrPortPhantomStatus INTEGER, s3TrPortPhantomChangeFlag INTEGER, s3TrPortChgSyn2IBM INTEGER, s3TrPortStrap INTEGER } s3TrPortBoardIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each board. Its value ranges between 1 and 12. The value for each board must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If a board is inserted or reinserted in a concentrator then the NMM has to be reinitialized." ::= { s3TrPortEntry 1 } s3TrPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique value for each port. Its value ranges between 1 and 12. The value for each port must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. If the board is an NMM board it will only have 2 ports, with Port 1 being for Ring In and Port 2 being for Ring Out." ::= { s3TrPortEntry 2 } s3TrPortWrap OBJECT-TYPE SYNTAX INTEGER { other(1), -- port not wrapped or connected wrap(2), connect(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Status of the port. Setting wrap(2) disconnects the port from the ring and setting this object to connect(3) connects the port to the ring." ::= { s3TrPortEntry 3 } s3TrPortTestLatch OBJECT-TYPE SYNTAX INTEGER { other(1), -- not supported on(2), -- test latch activated off(3) -- test latch not activated } ACCESS read-write STATUS mandatory DESCRIPTION "Status of the test latch which is used to set the channel decoder used to monitor the health of the communication path between the NMM and the module channel." ::= { s3TrPortEntry 4 } s3TrPortRelayStatus OBJECT-TYPE SYNTAX INTEGER { other(1), -- not supported on(2), -- channel is part of the ring off(3) -- channel is bypassed } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the channel's present relay mode. On(2) means the channel is in the ring and off(3) means the channel is bypassed." ::= { s3TrPortEntry 5 } s3TrPortPhantomStatus OBJECT-TYPE SYNTAX INTEGER { other(1), on(2), off(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Status of the ring access request signal." ::= { s3TrPortEntry 6 } s3TrPortPhantomChangeFlag OBJECT-TYPE SYNTAX INTEGER { other(1), noChange(2), change(3) } ACCESS read-only STATUS mandatory DESCRIPTION "Change(3) indicates that port phantom has been changed from OFF to ON. After inquiry by NMS, it will be cleared to noChange(2). Port phantom changing from ON to OFF has no impact on this object." ::= { s3TrPortEntry 7 } s3TrPortChgSyn2IBM OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), ibm(3) } ACCESS read-write STATUS mandatory DESCRIPTION "If the port is on a ring in/ring out module this object changes the strap state depending on the jumper setting retrieved as s3TrPortStrap. If the strap is set for SynOptics phantom option, this object can be changed to ibm(3). If the strap is set for non-SynOptics option, this object can not be changed. Non ring in/ring out modules or fiber ring in/ring out modules must take on the value of notSupported(1)." ::= { s3TrPortEntry 8 } s3TrPortStrap OBJECT-TYPE SYNTAX INTEGER { notSupported(1), synoptics(2), ibm(3) } ACCESS read-only STATUS mandatory DESCRIPTION "If the port is on a ring in/ring out module this object signifies whether the hardware jumper is in synoptics(2) mode or ibm(3) mode. This information is retrieved using a NMI command. For ports on fiber ring in/ring out modules, and those ports not on ring in/ring out modules, the agent always returns notSupported(1)." ::= { s3TrPortEntry 9 } -- SECTION 4: Token Ring NMM Group s3TrNmmFnNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the flat network number that this NMM is part of." ::= { s3000TrNmm 1 } s3TrNmmRingNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Defines the segment number that this NMM is connected to." ::= { s3000TrNmm 2 } s3TrNmmSlotNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Defines the slot number that this NMM is connected to. New NMS implementations should use the object s3AgentMySlotId defined in the common MIB." ::= { s3000TrNmm 3 } s3TrNmmFpuIdRev OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the Front-end Frame Processing unit. 0=Rev. A, 1=Rev. B, etc." ::= { s3000TrNmm 4 } s3TrNmmFpuStatus OBJECT-TYPE SYNTAX INTEGER { notPresent(1), notOperational(2), -- present, but not operational operational(3) -- present and operational } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the Front-end Frame Processing Unit." ::= { s3000TrNmm 5 } s3TrNmmDramSize OBJECT-TYPE SYNTAX INTEGER{ other(1), -- unknown size k512(2), -- 512K memory oneMeg(3), twoMeg(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The highest address of the DRAM in the NMM memory map." ::= { s3000TrNmm 6 } s3TrNmmEepromSize OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown size k2kby8(2), -- 2k*8 k8kby8(3) -- 8k*8 } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the EEPROM in the NMM memory map." ::= { s3000TrNmm 7 } s3TrNmmGrpAddrFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Group Address frames received without error by this NMM. Note: The NMM counts only Group Address frames that are addressed to its own Group Address(es)." ::= { s3000TrNmm 8 } s3TrNmmRing1or2 OBJECT-TYPE SYNTAX INTEGER { other(1), -- not a valid ring number ring1(2), -- use/using ring 1 on the concentrator ring2(3) -- use/using ring 2 on the concentrator } ACCESS read-only STATUS mandatory DESCRIPTION "Determines which ring the NMM is currently using on the concentrator backplane." ::= { s3000TrNmm 9 } s3TrNmmRingSpeed OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown speed speed1M(2), -- 1 Mbps for standard compatibility speed4M(3), -- 4 Mbps speed16M(4) -- 16 Mbps } ACCESS read-only STATUS mandatory DESCRIPTION "Token Ring speed." ::= { s3000TrNmm 10 } s3TrNmmHexDisplay OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "4 octet hex display string that is displayed on the NMM control panel." ::= { s3000TrNmm 11 } s3TrNmmEpromSize OBJECT-TYPE SYNTAX INTEGER { other(1), -- unknown size k2kby8(2), -- 2k*8 k8kby8(3), -- 8k*8 k16kby8(4), -- 16k*8 k32kby8(5), -- 32k*8 k64kby8(6), -- 64k*8 k128kby8(7), -- 128k*8 k256kby8(8) -- 256k*8 } ACCESS read-only STATUS mandatory DESCRIPTION "The size of the EPROM in the NMM memory map." ::= { s3000TrNmm 12 } -- SECTION 5: Token Ring Station Group -- Node table -- list of all nodes that are active on the local token ring that this -- concentrator is connected to. s3TrNodeTable OBJECT-TYPE SYNTAX SEQUENCE OF S3TrNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing station specific information." ::= { s3000TrNode 1 } s3TrNodeEntry OBJECT-TYPE SYNTAX S3TrNodeEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry in the table containing counters and profiling information for each node detected on the local token ring." INDEX { s3TrNodeEntMacAddress } ::= { s3TrNodeTable 1 } S3TrNodeEntry ::= SEQUENCE { s3TrNodeEntMacAddress OCTET STRING, s3TrNodeEntStatus INTEGER, s3TrNodeEntNodeStatus OCTET STRING, s3TrNodeLineErrs Counter, s3TrNodeBurstErrs Counter, s3TrNodeAriFciErrs Counter, s3TrNodeLostFrames Counter, s3TrNodeRcvCongestErrs Counter, s3TrNodeFrmCopyErrs Counter, s3TrNodeTokenErrs Counter, s3TrNodeInternalErrs Counter, s3TrNodeAbortTransErrs Counter, s3TrNodeFrequencyErrs Counter, s3TrNodeEntProductId OCTET STRING, s3TrNodeEntUna OCTET STRING, s3TrNodeEntNodeVersion OCTET STRING, s3TrNodeEntPhysDrop OCTET STRING, s3TrNodeEntFuncAddr OCTET STRING, s3TrNodeEntAuthFuncClass OCTET STRING, s3TrNodeEntAuthAccPriority OCTET STRING, s3TrNodeEntGrpAddr OCTET STRING, s3TrNodeEntStationId OCTET STRING, s3TrNodeEntBeaconType INTEGER, s3TrNodeBeaconCnt Counter, s3TrNodeLastBeaconTime TimeTicks, s3TrNodeLastInsertTime TimeTicks, s3TrNodeFirstInsertTime TimeTicks, s3TrNodeLastDeinsertTime TimeTicks, s3TrNodeRemoveStation INTEGER } s3TrNodeEntMacAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "MAC address of node that this entry in the table is for." ::= { s3TrNodeEntry 1 } s3TrNodeEntStatus OBJECT-TYPE SYNTAX INTEGER { beaconing(1), notBeaconing(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Tells whether the station is currently beaconing or not." ::= { s3TrNodeEntry 4 } s3TrNodeEntNodeStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Node status as defined in 802.5 specification (section 3.3.2.18)." ::= { s3TrNodeEntry 5 } s3TrNodeLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of line errors. Section 3.8.1 of IEEE 802.5 specification." ::= { s3TrNodeEntry 6 } s3TrNodeBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of burst errors. Section 3.8.3 of IEEE 802.5 specification." ::= { s3TrNodeEntry 7 } s3TrNodeAriFciErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of ARI FCI errors. See AC errors, Section 3.8.4 of IEEE 802.5 specification." ::= { s3TrNodeEntry 8 } s3TrNodeLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames lost. Section 3.8.6 of IEEE 802.5 specification." ::= { s3TrNodeEntry 9 } s3TrNodeRcvCongestErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive congestion errors. Section 3.8.7 of IEEE 802.5 specification." ::= { s3TrNodeEntry 10 } s3TrNodeFrmCopyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frame copy errors. Section 3.8.8 of IEEE 802.5 specification." ::= { s3TrNodeEntry 11 } s3TrNodeTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of token errors. Section 3.8.10 of IEEE 802.5 specification." ::= { s3TrNodeEntry 12 } s3TrNodeInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of internal errors. Section 3.8.2 of IEEE 802.5 specification." ::= { s3TrNodeEntry 13 } s3TrNodeAbortTransErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of abort delimiter transmitted errors. Section 3.8.5 of IEEE 802.5 specification." ::= { s3TrNodeEntry 14 } s3TrNodeFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frequency errors. Section 3.8.9 of IEEE 802.5 specification." ::= { s3TrNodeEntry 15 } s3TrNodeEntProductId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(18)) ACCESS read-only STATUS mandatory DESCRIPTION "A brief string describing the product specified by the vendor. Section 3.3.2.14 of IEEE 802.5 specification. The characters in the string are represented in EBCDIC for IBM products, in ASCII for others." ::= { s3TrNodeEntry 16 } s3TrNodeEntUna OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The Upstream Neighbor Address. Section 3.3.2.15 of IEEE 802.5 specification." ::= { s3TrNodeEntry 17 } s3TrNodeEntNodeVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(10)) ACCESS read-only STATUS mandatory DESCRIPTION "String that represents the version of the station software. Section 3.3.2.17 of IEEE 802.5 specification. The characters in the string are represented in EBCDIC for IBM products, in ASCII for others." ::= { s3TrNodeEntry 18 } s3TrNodeEntPhysDrop OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-only STATUS mandatory DESCRIPTION "This reports the physical location of this node on the ring. Section 3.3.2.13 of IEEE 802.5 specification." ::= { s3TrNodeEntry 19 } s3TrNodeEntFuncAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the functional addresses used by this station. Section 3.3.2.8 of IEEE 802.5 specification." ::= { s3TrNodeEntry 20 } s3TrNodeEntAuthFuncClass OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the functional classes that are allowed to be active in the station. Section 3.3.2.3 of IEEE 802.5 specification." ::= { s3TrNodeEntry 21 } s3TrNodeEntAuthAccPriority OBJECT-TYPE SYNTAX OCTET STRING (SIZE(2)) ACCESS read-only STATUS mandatory DESCRIPTION "The maximum priority this station is allowed to use. Section 3.3.2.2 of IEEE 802.5 specification." ::= { s3TrNodeEntry 22 } s3TrNodeEntGrpAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This contains the group address of this station. Section 3.3.2.9 of IEEE 802.5 specification." ::= { s3TrNodeEntry 23 } s3TrNodeEntStationId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "This string is used to uniquely identify the station. It may be equal to the station's MAC address. Section 3.3.2.21 of IEEE 802.5 specification." ::= { s3TrNodeEntry 24 } s3TrNodeEntBeaconType OBJECT-TYPE SYNTAX INTEGER { reconfiguration(1), signal-loss(2), bit-streaming(3), contention-streaming(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of beacon frame seen. Section 3.3.2.4 of IEEE 802.5 specification." ::= { s3TrNodeEntry 25 } s3TrNodeBeaconCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of beacon frames that have been sent by this station." ::= { s3TrNodeEntry 26 } s3TrNodeLastBeaconTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last beacon frame sent by this station." ::= { s3TrNodeEntry 27 } s3TrNodeLastInsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last ring insertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 28 } s3TrNodeFirstInsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the first ring insertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 29 } s3TrNodeLastDeinsertTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last ring deinsertion by this station. Time is relative from the system uptime." ::= { s3TrNodeEntry 30 } s3TrNodeRemoveStation OBJECT-TYPE SYNTAX INTEGER { other(1), -- do nothing remove(2) -- remove the MAC address } ACCESS read-write STATUS mandatory DESCRIPTION "Removes the MAC address associated with this entry from the ring by sending a REMOVE MAC frame if this object is written to with remove(2)." ::= { s3TrNodeEntry 31 } -- SECTION 6: Token Ring "RING" Group s3TrRingStatus OBJECT-TYPE SYNTAX INTEGER { beaconing(1), notbeaconing(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The status of the ring." ::= { s3TrRingStats 1 } s3TrRingFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received successfully by the NMM." ::= { s3TrRingStats 2 } s3TrRingOctetsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of octets received successfully by the NMM." ::= { s3TrRingStats 3 } s3TrRingBcastFrmsRxOk OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of broadcast frames received successfully by the NMM." ::= { s3TrRingStats 4 } s3TrRingLineErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of line errors. Section 3.8.1 of IEEE 802.5 specification." ::= { s3TrRingStats 5 } s3TrRingBurstErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of burst errors. Section 3.8.3 of IEEE 802.5 specification." ::= { s3TrRingStats 6 } s3TrRingAriFciErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of ARI FCI errors. See AC errors, Section 3.8.4 of IEEE 802.5 specification." ::= { s3TrRingStats 7 } s3TrRingLostFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames lost. Section 3.8.6 of IEEE 802.5 specification." ::= { s3TrRingStats 8 } s3TrRingRcvCongestErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive congestion errors. Section 3.8.7 of IEEE 802.5 specification." ::= { s3TrRingStats 9 } s3TrRingFrmCopyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frame copy errors. Section 3.8.8 of IEEE 802.5 specification." ::= { s3TrRingStats 10 } s3TrRingTokenErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of token errors. Section 3.8.10 of IEEE 802.5 specification." ::= { s3TrRingStats 11 } s3TrRingInternalErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of internal errors. Section 3.8.2 of IEEE 802.5 specification." ::= { s3TrRingStats 12 } s3TrRingAbortTransErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of abort delimiter transmitted errors. Section 3.8.5 of IEEE 802.5 specification." ::= { s3TrRingStats 13 } s3TrRingFrequencyErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frequency errors. Section 3.8.9 of IEEE 802.5 specification." ::= { s3TrRingStats 14 } s3TrRingBeaconCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of beacon frames that have been seen." ::= { s3TrRingStats 15 } s3TrRingBeaconType OBJECT-TYPE SYNTAX INTEGER { reconfiguration(1), signal-loss(2), bit-streaming(3), contention-streaming(4) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the type of beacon frame seen. Section 3.3.2.4 of IEEE 802.5 Specification." ::= { s3TrRingStats 16 } s3TrRingLastBeaconTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The time of the last beacon frame sent on the ring. Time is relative from the system uptime." ::= { s3TrRingStats 17 } s3TrRingBeaconStation OBJECT-TYPE SYNTAX OCTET STRING (SIZE(6)) ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of station last beaconing." ::= { s3TrRingStats 18 } END